...
Recherche
Fermer cette boîte de recherche.

Onduleur 12V 3KW à onde sinusoïdale pure pour véhicules de loisirs avec chargeur AC et MPPT

True Sine Wave AC Power
For operation of sensitive and motor loads
Extended Surge Rating
Surges to 3X conversion power for 2 seconds for motor loads
High Efficiency
Maximum conversion efficiency up to 92%
Wide 10.5-16.8 VDC Input Range
Ensures inverter operation on high voltage alternators found on many new vehicle chassis
Low Zero-Load Loss
The Zero-Load Loss can be as low as 10W
Built-in 30A AC Transfer Relay
Senses when outside AC Power is present and transfers the load from the inverter to the source of incoming power
High current charging
Because of using one circuit to realize the inverter and charger, the power of the charger is almost the same as that of the inverter
Programmable
Configurable 3 stage temperature compensated battery charge algorithm for optimal charging of almost any battery type up to 17V
Battery Equalization
Maximizes flooded battery life
Dead Battery Charging
Intermittence Charging, even Down to 0 Vdc
Power Share
Prioritizes AC loads by reducing the charge current and maintaining the total input current to less than the breaker setting

Specification Parameter

Fonctionnalité CF-1000-12 CF-1500-12 CF-2200-12 CF-3000-12
Control & Dimension
Remote Control CAN/RS485
Cooling Temperature & Load Controlled Cooling Fan
Dimension (W*H*D) 330*160*75mm 330*160*75mm 390*275*85mm 390*275*85mm
Packing 6KG 6KG 6.5KG 6.5KG
Inverter Mode
Nominal Voltage 12VDC
Input Voltage Range 10.5~16.8VDC
No Load Current 1A
Input Current (Max) 130A 190A 220A 250A
Stand-By Current 0.3A
Input Over Voltage Protection 17VDC
Input Under Voltage Protection 9VDC
Tension de sortie 220/230/240VAC ± 3%
Continuous Output Power 1000W ± 3% 1500W ± 3% 2200W ± 3% 3000W ± 3%
Surge Power 3000W 4500W 6600W 9000W
Output Waveform Pure Sine Wave (THD<3%)
Fréquence 50/60Hz ± 0.3%
Efficiency (Peak) ≥92%
Short-Circuit Protection Oui
INV. AC Output 5A Max 7A Max 10A Max 13A Max
Charger Mode
Nominal Voltage & Range 220/230/240VAC ± 20%
Frequency & Range 50/60Hz ± 3Hz (Auto-Adoptable)
AC Nominal Current 5.5A Max 8A Max 11A Max 15A Max
Efficiency (Peak) ≥92%
AC Input Current (Max) 12A Max 17A Max 25A Max 32A Max
Power Factor Correction (PFC) ≥0.99
Max. Output Voltage Range 9~17VDC
DC Output Current Range 0~72A 0~100A 0~150A 0~205A
Battery Temp. Compensation -25mV per °C Max
Protection de l'environnement
Battery Side Over Voltage/Under Voltage/Reverse Polarity
Battery Temp. Protection Battery Temperature Sensor (Optional)
AC Side AC Output Protection: Short Circuit/Overload
AC Input Protection Over Voltage / Under Voltage
Others Temperature Protection, Fan Error Protection, Internal Error Protection
Environment
Working Temp. Range -20°C~50°C
Power De-rating (51°C~60°C) 33W per °C 50W per °C 73W per °C 100W per °C
Storage Temp. -40°C~70°C
Working Humidity Range 5~95% RH Non-Condensing

 

Produits apparentés

Découvrez les onduleurs de premier plan dans notre section produits, chacun d'entre eux étant conçu pour une efficacité et une fiabilité maximales dans n'importe quel environnement.

Nos blogs

Plongez dans nos blogs pour y trouver des articles pertinents sur la technologie des onduleurs, les tendances énergétiques et des conseils pour optimiser vos solutions d'alimentation.